Arq. bras. oftalmol ; 71(2): 228-233, mar.-abr. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-483031

ABSTRACT

OBJETIVO: Verificar a reprodutibilidade da classificação dos padrões do teste de cristalização do filme lacrimal utilizando cinco examinadores diferentes e comparar os padrões de cristalização de pacientes portadores da síndrome de Sjõgren com os de indivíduos não portadores de doenças da superfície ocular. MÉTODOS: Análise da cristalização da lágrima de 29 pacientes com Sjõgren e 45 pacientes sem doenças da superfície ocular, através de microscópio com luz polarizada, utilizando a classificação de Rolando. Para fins estatísticos foi estudada a curva ROC (Receiver Operating Characteristic) para determinar a melhor nota de corte do exame que separa indivíduos normais dos portadores da síndrome, índice de concordância Kappa (p<0,0001) para averiguar a reprodutibilidade da classificação dos padrões de cristalização e tabelas de contingência para comparação dos resultados entre os grupos. RESULTADOS: Com os padrões agregados (I com II e III com IV) a concordância dos examinadores foi alta (Kappa=0,82 a 0,97 e p<0,0001). Por meio da curva ROC obtivemos nota de corte de 2,50 para o diagnóstico de Sjõgren. Na comparação entre os grupos, o grupo normal recebeu predominantemente classificações de padrões I e II, ao passo que o grupo com Sjõgren, padrões III e IV. CONCLUSÕES: Houve concordância com a literatura quanto aos padrões encontrados nos pacientes com Sjõgren e nos pacientes sem doença da superfície ocular. A classificação do teste de cristalização é reprodutível quando utilizada a classificação de Rolando.


PURPOSE: To verify the reproducibility of Rolando's classification of the tear ferning test using five different examiners and to compare the patterns of crystallization found in Sjõgren's syndrome patients and normal subjects. METHODS: Tear ferning analysis of 29 patients with Sjõgren's syndrome and of 45 patients without ocular disease were done using polarized light microscopy and the Rolando classification for tear ferning. Five examiners classified the ferning patterns of all the patients. ROC curve (Receiver Operating Characteristic) was used to find out the best score for the correct syndrome diagnosis. Kappa index (p<0.0001) was used to compare the results of the examiners among them and check the test's reproducibility. Charts were drawn to compare the two groups' results. RESULTS: Throught the ROC curve the score of 2.50 for diagnosis of Sjõgren's syndrome was stabilished. Considering the aggregated patterns I with II and III with IV, the examinors' level of pattern agreement was excellent (Kappa ranging from 0.82 to 0.97, p<0.0001). The group with Sjõgren's syndrome was classified mostly as patterns III and IV and the patients without ocular disease mostly as I and II. CONCLUSION: The patterns associated with Sjõgren's syndrome and normal patients matched the ones in the literature. The tear ferning test classification is reproductible when the Rolando classification was used for Sjõgren's syndrome patients.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Diagnostic Techniques, Ophthalmological , Sjogren's Syndrome/diagnosis , Tears/chemistry , Crystallization/classification , Epidemiologic Methods , Observer Variation
SELECTION OF CITATIONS
SEARCH DETAIL